Quantity
|
Out of stock
|
||
|
|
|||
Stainless steel compression load cells designed for weighing tanks and hoppers, compatible with relevant mounting accessories.
Capacities (kg):
250, 500, 1,000, 2,500, 5,000, 7,500, 10,000, 12,500, 15,000, 30,000, 50,000, 100,000
Accuracy:
OIML R60, C3 accuracy class from 2,500 to 12,500 kg
Material: Stainless steel
Protection: IP68 / IP69K
MAIN FEATURES
-
Capacities from 250 to 100,000 kg
-
OIML C3 approved (from 2,500 to 12,500 kg)
-
Low-profile design
-
High resistance to lateral forces
-
Stainless steel construction
-
IP68 protection, IP69K available on request
-
Shielded connection cable
TECHNICAL FEATURES
-
Minimum verification interval: Vmin = Emax / 10,000
-
Rated output (FSO): 2 mV/V ± 0.5%
-
Non-repeatability: 0.01% F.S.
-
Combined error: 0.05%
-
Temperature effect on zero: 0.02% / 10°C
-
Temperature effect on full scale output: 0.02% / 10°C
-
Compensated temperature range: –10°C to +40°C
-
Operating temperature range: –20°C to +60°C
-
Creep (30 minutes): 0.02% F.S.
-
Maximum excitation voltage: 15 VDC
-
Input resistance: 750 ± 10 Ω
-
Output resistance: 700 ± 5 Ω
-
Zero balance: ±1% F.S.
-
Insulation resistance: > 5,000 MΩ
-
Safe overload: 120% F.S.
Cable:
4-wire shielded cable, Ø 5 mm
-
5 m for CPX 250…5,000 versions
-
10 m for CPX 7,500…100,000 versions
ATEX VERSION
The CCATEX certificate qualifies the load cell for use in hazardous areas with the following protection methods:
-
ATEX II 1G Ex ia IIC T6 (Ta –20 to +40°C)
TX (Ta –20 to +65°C) Ga -
ATEX II 1D Ex ta IIIC TX°C (Ta –20 to +40°C)
TX°C (Ta –20 to +65°C) Da, IP65
The certificate includes the user manual and the ATEX CE Declaration of Conformity (available in EN, DE, FR, and IT).
Each CCATEX certificate is issued individually after inspection by qualified technicians using dedicated test equipment.
Important:
The certificate applies to a single load cell. For systems with multiple load cells, a separate certificate must be ordered for each unit.
MAIN CERTIFICATIONS
-
OIML R60
-
Australian Legal for Trade Certificate of Approval (NMI S843)
.